The Efficacy of Continuous Venovenous Hemodiafiltration with Cytokine Filter on Sepsis


YILDIRIM M. , ÖZDEMİR KOL İ. , AVCI O. , Gulsoy Z., KAYGUSUZ K. , GÜRSOY S.

ERCIYES MEDICAL JOURNAL, vol.42, no.1, pp.54-59, 2020 (Journal Indexed in ESCI) identifier

  • Publication Type: Article / Article
  • Volume: 42 Issue: 1
  • Publication Date: 2020
  • Doi Number: 10.14744/etd.2019.22599
  • Title of Journal : ERCIYES MEDICAL JOURNAL
  • Page Numbers: pp.54-59

Abstract

Objective: Continuous renal replacement therapy is made with high biocompatibility membranes that have high current power by using diffusion and convection together or separately. The aim of the present study was to compare the EMIC-2 and AV600S filters used for continuous venovenous hemodiafiltration (CVVHDF) with respect to the effects on sepsis, the elimination of toxins that are elevated due to acute renal injury, and the effects on inflammatory mediators in severe sepsis.