Frontal QRS-T angle as a predictive marker for myocardial damage in acute carbon monoxide poisoning


TEKİN Y. K., TEKİN G., NUR N., KORKMAZ İ., YURTBAY S.

HUMAN & EXPERIMENTAL TOXICOLOGY, cilt.40, sa.12_SUPPL, 2021 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 40 Sayı: 12_SUPPL
  • Basım Tarihi: 2021
  • Doi Numarası: 10.1177/09603271211043477
  • Dergi Adı: HUMAN & EXPERIMENTAL TOXICOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, PASCAL, BIOSIS, CAB Abstracts, Chimica, CINAHL, EMBASE, Environment Index, Food Science & Technology Abstracts, MEDLINE, Pollution Abstracts, Veterinary Science Database
  • Anahtar Kelimeler: Carbon monoxide poisoning, electrocardiography, frontal QRS-T angle, LONG-TERM MORTALITY, CARDIAC TROPONIN-T, PROGNOSTIC VALUE, ATHEROSCLEROSIS RISK, INFARCTION, ASSOCIATION, DEATH, PATHOPHYSIOLOGY, STRATIFICATION, EXPOSURE
  • Sivas Cumhuriyet Üniversitesi Adresli: Evet

Özet

Introduction The present study was undertaken to investigate the prognostic value of the frontal QRS-T angle associated with adverse cardiac outcomes in patients with carbon monoxide (CO) poisoning in early stages in the emergency department. Materials and methods The data of 212 patients with CO poisoning who were admitted to the ED between January 2010 and May 2020 were retrospectively analyzed. The frontal QRS-T angle was obtained from the automatic reports of the EKG device. Results Compared to patients without myocardial damage, among patients with myocardial damage, statistically high creatinine, creatine kinase MB, cardiac troponin I, and frontal QRS-T angle values were found (p < 0.001 for all parameters), while the saturation of arterial blood pH and arterial oxygen values were found to be lower (p = 0.002 and p < 0.001, respectively). The frontal QRS-T angle values were correlated with creatine kinase, creatine kinase-MB, cardiac troponin I, and oxygen saturation (SpO(2)) in arterial blood (r = 0. 232, p = 0.001; r = 0. 253, p = < 0.001; r = 0. 389, p = < 0.001; r = -0. 198, p = 0.004, respectively). The optimum cut-off value of the frontal QRS-T angle was found to be 44.5 (area under the curve: 0.901, 95% confidence interval: 0.814-0.988, sensitivity: 87%, specificity: 84%). Conclusions The frontal QRS-T angle, a simple and inexpensive parameter that can be easily obtained from 12-lead surface electrocardiography, can be used as an early indicator in the detection of myocardial damage in patients with CO poisoning.