Evaluation of a sternum dehiscence reconstruction graft on an animal model
Medicine Science International Medical Journal, cilt.11, sa.2, ss.598-602, 2022 (TRDizin)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 11 Sayı: 2
- Basım Tarihi: 2022
- Doi Numarası: 10.5455/medscience.2021.10.356
- Dergi Adı: Medicine Science International Medical Journal
- Derginin Tarandığı İndeksler: EBSCO Legal Collection, TR DİZİN (ULAKBİM)
- Sayfa Sayıları: ss.598-602
- Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
- Sivas Cumhuriyet Üniversitesi Adresli: Evet
Özet
Sternum dehiscence occurring after surgeries requiring median incision of the sternum remains a current problem. New materials are needed to prevent or reduce the risk
of developing sternum dehiscence. In this study, the effects of extracellular matrix (ECM)-like sternum dehiscence graft in a rabbit model were investigated. A total of
24 rabbits in three groups were used in the study. There were eight rabbits in each group. The first group was the control group, the second group was the conventional
closure method, and the third group was the sternum closure graft group. Median sternotomy was applied to the rabbits in the second and third groups. Animals were
sacrificed 4 weeks after surgery and sternum samples were taken. Sternum samples taken from untreated animals had normal histological appearance. Cartilage formation
and fibrocyte-fibroblast activity were mild in the conventional surgery group, while moderate in the reconstruction graft group. It has been shown histopathologically that
sternum closure graft accelerates bone healing (P= 0.015). It is obvious that if this graft is used clinically, it will reduce the incidence of sternum dehiscence.