Application of a novel poly(SMAm)-Tris-Fe3O4 nanocomposite for selective extraction and enrichment of Cu(I) /Cu(II) from beer, soft drinks and wine samples, and speciation analysis by micro-volume UV-Vis spectrophotometry


ZENGİN H., GÜRKAN R.

TALANTA, cilt.224, 2021 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 224
  • Basım Tarihi: 2021
  • Doi Numarası: 10.1016/j.talanta.2020.121789
  • Dergi Adı: TALANTA
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, L'Année philologique, Aerospace Database, Analytical Abstracts, Aqualine, Aquatic Science & Fisheries Abstracts (ASFA), BIOSIS, CAB Abstracts, Chemical Abstracts Core, Communication Abstracts, EMBASE, Food Science & Technology Abstracts, Linguistic Bibliography, MEDLINE, Metadex, Pollution Abstracts, Veterinary Science Database, Civil Engineering Abstracts
  • Anahtar Kelimeler: Copper speciation, Nanocomposite, Poly(SMAm) copolymer, Tris, UA-CPE, Micro-volume UV-vis spectrophotometry, SOLID-PHASE EXTRACTION, CLOUD-POINT-EXTRACTION, TRACE AMOUNTS, METAL-IONS, COPPER II, PRECONCENTRATION, WATER, LEAD, STABILIZATION, SPECTROMETRY
  • Sivas Cumhuriyet Üniversitesi Adresli: Evet

Özet

In this study, a novel functional nanocomposite was synthesized, characterized and selectively used in pH-controlled separation, pre-concentration and speciation analysis of Cu(I) and Cu(II) from sample matrices where extraction is assisted, facilitated and greatly enhanced by ultrasound energy. The hydrophilic composite material functionalized with tris(2-hydroxymethyl)aminomethane (Tris) and Fe3O4 NPs was characterized in detail by ATR-FT-IR, H-1 NMR, XRD, EDX peaks and SEM images. After optimization of the main variables influencing extraction efficiency such as pH, volumes of buffer, modified copolymer in acetone, CTAB and Triton X-114 at fixed concentrations including sonication conditions, the Cu(I) and Cu(II) were monitored against a blank at 347 nm by micro-volume UV-vis spectrophotometer. A good linearity was obtained in the range of 2-140 and 5-150 mu g L-1 for Cu(II) and Cu(I) with r(2) >= 0.993. The limits of detection (LODs) of 0.66 and 1.60 mu g L-1 for each analyte, were obtained from a pre-concentration of 70-fold. After validation, the method was applied to speciation of Cu(I), Cu(II), and total Cu in the pre-treated and diluted beverage samples before and after pre-oxidation of Cu(I) to Cu(II) due to be more sensitive of extraction process to Cu(II) at pH 6.0. The results were also compared with those obtained by FAAS analysis to ensure the reliability of the results. It was observed that there was a statistically good agreement between the results of both methods.