Synthesis, characterization and application of cross-linked functional terpolymer through epoxy group as sorbent for extraction of cadmium from waters and foods: Multivariate optimization


Yılmaz E., BOZTUĞ A., Ul Haq H., Boczkaj G., ALTUNAY N.

Food Chemistry, cilt.435, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 435
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1016/j.foodchem.2023.137590
  • Dergi Adı: Food Chemistry
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, PASCAL, Aerospace Database, Aquatic Science & Fisheries Abstracts (ASFA), BIOSIS, CAB Abstracts, Chemical Abstracts Core, Chimica, Communication Abstracts, Compendex, EMBASE, Food Science & Technology Abstracts, Metadex, Veterinary Science Database, Civil Engineering Abstracts
  • Anahtar Kelimeler: Adsorbents, Environmental pollution, Food analysis, Functional materials, Heavy metals, Water environmental monitoring
  • Sivas Cumhuriyet Üniversitesi Adresli: Evet

Özet

The purpose of this study was to develop a selective sorbent for cadmium ions (Cd(II)) enrichment in orbital shaker assisted solid phase microextraction (OS-SPME) from different aqueous and food samples. A maleic anhydride-styrene-glycidyl methacrylate (MA-St-GMA) terpolymer was synthesized and characterized in detail. Experimental variables of sample preparation step were optimized using a central composite design (CCD). The final determination step was performed using flame atomic absorption spectroscopy (FAAS). The MA-St-GMA sorbent exhibited a high adsorption capacity (195.9 mg g−1) for the Cd(II) ion. The developed method under optimal conditions provides satisfactory performance and a significant improvement compared to other protocols available in the literature. The linear range and detection limit of the method is 0.1–130 ng mL−1 and 0.03 ng mL−1, respectively. The robustness, intraday/interday precision, selectivity, and accuracy of the method were investigated. To further validate the method, a dedicated series of analysis was performed using certified reference materials (CRMs). This part of the study confirmed the applicability of the method for routine analysis. The OS-SPME-FAAS method was validated using water and food samples. Relative standard deviations and recovery for real-world samples were in ranges 1.7–2.2 % and 95.5–98.5 %, respectively. As a result, the MA-St-GMA sorbent showed that it could quantitatively extract Cd(II) ions from aqueous solution.