Thermohydraulic performance study of different square baffle angles in cross-corrugated channel


Creative Commons License

Alnak D. E.

JOURNAL OF ENERGY STORAGE, cilt.28, ss.101295, 2020 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 28
  • Basım Tarihi: 2020
  • Doi Numarası: 10.1016/j.est.2020.101295
  • Dergi Adı: JOURNAL OF ENERGY STORAGE
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Compendex, INSPEC
  • Sayfa Sayıları: ss.101295
  • Anahtar Kelimeler: Baffle, Cross-corrugated duct, Heat transfer, Plate heat exchanger, HEAT-TRANSFER, TURBULENT-FLOW, MASS-TRANSPORT, PRESSURE-DROP, EXCHANGER, SURFACES, DUCTS
  • Sivas Cumhuriyet Üniversitesi Adresli: Evet

Özet

Cross-corrugated channels implementing high heat transfer performance are proper to employ in plate fin heat

exchangers. In this work, the heat transfer, pressure drop and thermohydraulic performance in the cross-corrugated

triangular channels having rectangle baffles with different settlement angles are numerically researched.

Ansys-Fluent program is performed to solve Navier Stokes and energy equations by using k-ε turbulence model in

numerical calculations. While air inlet temperature employed as working fluid is 293 K, wall surface temperature

values of the lower corrugated duct are taken as constant 373 K. The constant rectangle baffle height and apex

angle of the corrugated channel are utilized as 0.5 H and 60°, respectively. Re number range analyzed in this

work is 1000–6000 while the rectangle baffle settlement angles are 30°,45°,60° and 90°. Numerical results are

agreed with 3.53% deviation according to experimental study existed in literature. The attained results are

exhibited as mean Nu number, fluid temperature and pressure variations for each rectangle baffle angle. Contour

distributions of the temperature and velocity vector are also evaluated for different Re numbers and rectangle

baffle angles. The Num value for the corrugated channel with rectangle baffle of 90° angle is 52.8% higher than

that of the 60° for the Re = 6000. Also, for Re = 1000 the value of the pressure drop is 65.97% lower in the

corrugated triangular channel with 60° rectangle baffle angle than that of 90° angle.