Application of ultrasonic-assisted cloud point extraction/flame atomic absorption spectrometry (UA-CPE/FAAS) for preconcentration and determination of low levels of antimony in some beverage samples


GÜRKAN R., Eser M.

JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, cilt.13, sa.9, ss.1579-1591, 2016 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 13 Sayı: 9
  • Basım Tarihi: 2016
  • Doi Numarası: 10.1007/s13738-016-0874-2
  • Dergi Adı: JOURNAL OF THE IRANIAN CHEMICAL SOCIETY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1579-1591
  • Anahtar Kelimeler: Antimony, Chelating agents, SDS/Tween 80, UA-CPE, FAAS, Beverages/milk products, LIQUID-LIQUID MICROEXTRACTION, SINGLE-DROP MICROEXTRACTION, SODIUM DODECYL-SULFATE, INORGANIC ANTIMONY, SPECTROPHOTOMETRIC DETERMINATION, NATURAL-WATERS, HYDRIDE GENERATION, EMULSIFICATION MICROEXTRACTION, EMISSION-SPECTROMETRY, BIOLOGICAL SAMPLES
  • Sivas Cumhuriyet Üniversitesi Adresli: Evet

Özet

Due to be able to migrate or leach from food packaging materials into the foods and/or beverages, development of a new, sensitive and selective analytical methods for low levels of antimony as a food contaminant is of great importance in terms of food safety. In this context, an ultrasonic-assisted cloud point extraction method was developed for the preconcentration and determination of antimony as Sb(III) using 4-(2-thiazolylazo)resorcinol (TAR) and 2-(2-thiazolylazo)-p-cresol (TAC) as chelating agents and sodium dodecyl sulfate as signal enhancing agent at pH 6.0 and mediated by nonionic surfactant, t-octylphenoxypolyethoxyethanol by flame atomic absorption spectrometry. Using the optimized conditions, the calibration curves obtained from Sb(III) with TAR and TAC were linear in the concentration ranges of 0.5-180 and 1-180 mu g L-1 with detection limits of 0.13 and 0.28 mu g L-1, respectively. The precision (as relative standard deviations, RSDs) was lower than 3.9 % (25 and 100 mu g L-1, n: 6). The method accuracy was validated by the analysis of two standard reference materials. The results obtained were statistically in a good agreement with the certified values at 95 % confidence limit. The method has successfully been applied to the determination of Sb(III) and total Sb in selected beverages, milk and fruit-flavored milk products before and after pre-reduction of Sb(V) to Sb(III) with a mixture of KI/ascorbic acid in acidic media. The Sb(V) contents of samples were quantitatively calculated from analytical difference between total Sb and Sb(III) levels.